Ionic boilers range

Une gamme complète pour répondre à tous les besoins
Performances
Area (m²)/heated volume (m³)
Insulated houses type RT 2012
≤ 60 m² / ≤ 150 m³
Power supply
Type Single phase
Rated voltage 230 Vac
Rated power 3 KW
Phase intensity (water)* 13 A
Section 6 mm²
Electrical protection class IP21
Hydraulic
Temperature setting* 30-60°C
Primary circuit water capacity (salt water) 1,5 L
Primary circuit operating pressure 0,5 bar max
Heating system connectors 3/4”
Number of plates of the main exchanger 14
Circuit water capacity secondary boiler 0,75 L
Load lossiness of the boiler to 1000 L/h 0,75 mCe
Weight and dimensions
Width 350 mm
Height 700 mm
Thickness 270 mm
Weight 16 Kg
Performances
Area (m²)/heated volume (m³)
Insulated houses type RT 2012
≤ 120 m² / ≤ 300 m³
Power supply
Type Single phase
Rated voltage 230 Vac
Rated power 6 KW
Phase intensity (water)* 26 A
Section 6 mm²
Electrical protection class IP21
Hydraulic
Temperature setting* 30-60°C
Primary circuit water capacity (salt water) 1,5 L
Primary circuit operating pressure 0,5 bar max
Heating system connectors 3/4”
Number of plates of the main exchanger 14
Circuit water capacity secondary boiler 0,75 L
Load lossiness of the boiler to 1000 L/h 0,75 mCe
Weight and dimensions
Width 350 mm
Height 700 mm
Thickness 270 mm
Weight 17 Kg
Performances
Area (m²)/heated volume (m³)
Insulated houses type RT 2012
≤ 180 m² / ≤ 450 m³
Power supply
Type Single phase
Rated voltage 230 Vac
Rated power 9 KW
Phase intensity (water)* 39 A
Section 10 mm²
Electrical protection class IP21
Hydraulic
Temperature setting* 30-60°C
Primary circuit water capacity (salt water) 2,5 L
Primary circuit operating pressure 0,5 bar max
Heating system connectors 3/4”
Number of plates of the main exchanger 30
Circuit water capacity secondary boiler 1 L
Load lossiness of the boiler to 1000 L/h 0,75 mCe
Weight and dimensions
Width 350 mm
Height 700 mm
Thickness 270 mm
Weight 21 Kg
Performances
Area (m²)/heated volume (m³)
Insulated houses type RT 2012
≤ 240 m² / ≤ 600 m³
Power supply
Type Single phase
Rated voltage 230 Vac
Rated power 12 KW
Phase intensity (water)* 54 A
Section 10 mm²
Electrical protection class IP21
Hydraulic
Temperature setting* 30-60°C
Primary circuit water capacity (salt water) 3 L
Primary circuit operating pressure 0,5 bar max
Heating system connectors 3/4”
Number of plates of the main exchanger 30
Circuit water capacity secondary boiler 1 L
Load lossiness of the boiler to 1000 L/h 0,75 mCe
Weight and dimensions
Width 350 mm
Height 700 mm
Thickness 270 mm
Weight 21 Kg
Performances
Area (m²)/heated volume (m³)
Insulated houses type RT 2012
≤ 180 m² / ≤ 450 m³
Power supply
Type Single phase
Rated voltage 400 Vac
Rated power 9 KW
Phase intensity (water)* 13 A/phase 18 A
Section 6 mm²
Electrical protection class IP21
Hydraulic
Temperature setting* 30-60°C
Primary circuit water capacity (salt water) 2,5 L
Primary circuit operating pressure 0,5 bar max
Heating system connectors 3/4”
Number of plates of the main exchanger 30
Circuit water capacity secondary boiler 1 L
Load lossiness of the boiler to 1000 L/h 0,75 mCe
Weight and dimensions
Width 350 mm
Height 700 mm
Thickness 270 mm
Weight 21 Kg
Performances
Area (m²)/heated volume (m³)
Insulated houses type RT 2012
≤ 240 m² / ≤ 600 m³
Power supply
Type Single phase
Rated voltage 400 Vac
Rated power 12 KW
Phase intensity (water)* 18 A/phase
Section 6 mm²
Electrical protection class IP21
Hydraulic
Temperature setting* 30-60°C
Primary circuit water capacity (salt water) 3 L
Primary circuit operating pressure 0,5 bar max
Heating system connectors 3/4”
Number of plates of the main exchanger 30
Circuit water capacity secondary boiler 1 L
Load lossiness of the boiler to 1000 L/h 0,75 mCe
Weight and dimensions
Width 350 mm
Height 700 mm
Thickness 270 mm
Weight 21 Kg
Performances
Area (m²)/heated volume (m³)
Insulated houses type RT 2012
≤ 300 m² / ≤ 750 m³
Power supply
Type Single phase
Rated voltage 400 Vac
Rated power 15 KW
Phase intensity (water)* 21,6 A/phase
Section 6 mm²
Electrical protection class IP21
Hydraulic
Temperature setting* 30-60°C
Primary circuit water capacity (salt water) 3,5 L
Primary circuit operating pressure 0,5 bar max
Heating system connectors 3/4”
Number of plates of the main exchanger 30
Circuit water capacity secondary boiler 1 L
Load lossiness of the boiler to 1000 L/h 0,75 mCe
Weight and dimensions
Width 350 mm
Height 700 mm
Thickness 270 mm
Weight 22 Kg
Performances
Area (m²)/heated volume (m³)
Insulated houses type RT 2012
≤ 500 m² / ≤ 1250 m³
Power supply
Type Three-phase
Rated voltage 400 Vac
Rated power 25 KW
Phase intensity (water)* 36 A/phase
Section 10 mm²
Electrical protection class IP21
Hydraulic
Temperature setting* 30-60°C
Primary circuit water capacity (salt water) 4 L
Primary circuit operating pressure 0,5 bar max
Heating system connectors 3/4”
Number of plates of the main exchanger 30
Circuit water capacity secondary boiler 1 L
Load lossiness of the boiler to 1000 L/h 0,75 mCe
Weight and dimensions
Width 350 mm
Height 700 mm
Thickness 270 mm
Weight 24 Kg